Atlas Copco Compressor Fault Codes – Atlas Copco Compressor Troubleshooting

Hey! This site is reader-supported and we earn commissions if you purchase products from retailers after clicking on a link from our site.

A common problem with Atlas Copco air compressors is Atlas Copco compressor fault codes. This article will provide you with some useful information on compressor error codes, along with existing reader questions and responses about Atlas Copco compressor fault codes!

Reasons Atlas Copco Compressor Shows Fault Codes

The fault codes displayed on the Atlas Copco air compressor should be separated into unit faults (ERR/ERROR), and system alarms (SYS/WARNING).

When the compressor displays an error or shutdown, the conditions of the error will automatically reset once the condition has been resolved and the air compressor has restarted, working with no issues.

System Fault

When the compressor displays a system alarm warning, the conditions are automatically reset when the condition has been resolved and reset on the compressor.

It’s common for the fault codes to be separated by some regarding a problem or error with the controller itself which prevents normal operation of the compressor, and system faults that occur externally from the controller and with the compressor.

The Atlas Copco compressor fault codes will likely show their errors in two different light patterns:

Reader Questions & Responses

I’m working with a new Atlas Copco 50 hp IVR reciprocating air compressor.

My problem is when I start the compressor after a few minutes it shows COMPRESSOR MOTOR CONVERTER TIME OUT.

I have reset but repeatedly it shows the same error.

Please let me know what is the actual problem.

Читайте также:  Код ошибки le1 на стиральной машинке самсунг что значит

Thank you in advance!

250z Atlas Copco (fault) compressor motor converter time out – does anyone know what the cause is

I have the same issue with my ZR250VSD. after completing maintenance, we turned on the power, started, and appeared the error “converter time out”, could not reset. now waiting for OEM to come.

* Check communication cable* Isolate the converter from the module, and use the VSD simulation software to test whether the module or converter is at fault.

Atlas Copco Compressor Showing JDEC Warning – Atlas Copco Compressor Fault Codes JDEC

JDEC warning unAck on display what does that mean?

Typically, a device is being polled but is not responding. That’s about my understanding of it.

Has anyone heard from Atlas Copco on this issue?

What is causing an expansion module error on the compressor which I have to power reset to start the compressor back up?

SIOE module in the comm box

With luck, you can just r/r it, maybe clean contacts if just re-seating doesn’t do it.

Failing that, check the module for obvious problems like burnt components, bad solder joints, etc.

Give me your email address. I will show you a video of the error.

(Saad, rather than one email address, please provide a link to the video as a comment here so that all can see it. Thank you. Moderator)

XAHS 273 Atlas Copco Stop Fault code –

I have an air compressor (XAHS 273, Atlas Copco),

I can start the compressor without a problem and load with air normally, but the issue is when I’m trying to switch it off the engine does not stop, it displays (stop failure) even when I press emergency the engine keeps working and never stop

Читайте также:  Сканер штрих кода ошибка при подключении не удалось загрузить внешнюю компоненту

Note that before I start the engine, it displays an EIC warning Unack

Atlas Copco XAS 273 construction compressor

Please help and many thanks in advance

Well, there are two main ways to stop a diesel, cut off the fuel or the air. Emergency stop (at least in North America) cuts off the air intake so it can’t run on environmental fumes.

So, it’s getting air when it shouldn’t, and probably the Unack is telling you there is some fault with the engine air control device.

XAX 300 Atlas Copco Compressor Temp Fault

The compressor has not run yet, it is not overheated and in testing, I do not have a signal/voltage going to the temp sensor under the compressor.

Removed wires and temp probe is “open” and tested the wires going to it and they have no voltage to them on either red or blue wire.

Is there something to check? Fuse?

Atlas Copco XAS 300 air compressor

I’m going to guess that your compressor is an XAS 300 as opposed to XAX 300?

If it were a fuse, looks like the whole panel would be down.

TS is normally closed, so as a test, try shorting the wires to it. That should satisfy the controller.

If not, check the wiring.

If so, then replace TS.

Hi anyone who can help,

We have an Atlas Copco XAS 375 JD6 screw compressor here on-site in PNG.

Its displaying “internal error unack”, also “sensor fail S unack”.

Atlas Copco XAS-375 air compressor

Now we all know that “unack” is UNACKNOWLEDGED. But what is the machine referring to by “internal error”?

Читайте также:  Ошибка магазина код ошибки 80070057

Internal of the control panel?

It’s a game of musical chairs to remove any faults on the control panel and the machine won’t start the start cycle/preheat either.

Here’s what has been done:

If so we would really appreciate the help people, we are up the creek no paddle.

(If you have these documents or .pdf files, they can be uploaded using the comment form at the end of this page. Moderator)

Sounds like the sensor is the root.

If you can find it/them I’d check the wires at the sensor ends.

With luck, you can disconnect them in turn, and the one that doesn’t present a new unack will be the faulty one.

If you have any questions regarding Atlas Copco air compressor fault codes, please leave a comment below, with a photo if applicable, so that someone can help you!